Want tender expert help? See our tender preparation service
Tenders

Execution of design documentation for the task entitled "Heritage in Greenery - modernization and transformation of historic buildings in the Ecological Center", within the framework of the Polish-Swiss Urban Development Program

Closed

Updated November 24, 2026

Submission Deadline Has Passed

This tender's submission deadline has passed and is no longer accepting applications. The information below is kept for reference purposes.

Browse Active Tenders
Deadline
Expired
March 04, 2026
Contract Details
Category
Services
Reference
2026/BZP 00125181/01
Value
zł162,602
Location
Wielkopolskie, Poland
Published
November 17, 2026
CPV Code
Project Timeline

Tender Published

February 24, 2026

Deadline for Questions

February 25, 2026

Submission Deadline

March 04, 2026

Win ProbabilityPRO
🔒
Upgrade to Professional
See your estimated win probability based on historical data.
Upgrade to Professional →
Buyer IntelligencePRO
🔒
Unlock Buyer Intelligence
See spending patterns, preferred procedures, and more.
Upgrade to Professional →
Sector InsightsPRO
🔒
Unlock Sector Insights
See average winning prices, competition levels, and market trends.
Upgrade to Professional →

Key facts

Estimated value
zł162,602
Deadline
Expired
CPV Code
71000000-8 — Architectural, construction, engineering and inspection services
Budget
zł162,602
Duration
Not specified
Location
Wielkopolskie
Type
Services
75
Quality Score/100
Good
Market Benchmark
Avg. Winning Price
€496,142
Avg. Bids
0.6
Competition
Low
SME Winners
93%
25,840 tenders analyzed

Original Tender Description

Execution of design documentation for the task entitled "Heritage in Greenery - modernization and transformation of historic buildings in the Ecological Center", within the framework of the Polish-Swiss Urban Development Program
EU Funded

Run Risk Analysis

Identify potential risks, inconsistencies, and red flags across all tender documents. Get a detailed risk report with severity levels and mitigation recommendations.

Login

Win Strategy

AI-powered analysis of this tender's requirements, opportunities, and challenges. Get strategic insights to maximize your win probability.

65%
Estimated Win ProbabilityModerate Fit

This tender requires comprehensive design documentation for the revitalization of a historic building into an Ecological Center. A winning bid will emphasize deep expertise in historic building renovation, integrated design services, and a clear understanding of the Polish-Swiss Urban Development Program's objectives, despite the lack of explicit evaluation criteria.

Key Winning Messages

Expertise in Historic Building Revitalization and Adaptive Reuse

Integrated Design Excellence for a Sustainable Ecological Center

Commitment to the Polish-Swiss Urban Development Program's Vision

Key Opportunities
Leverage the Polish-Swiss Urban Development Program context to align the bid with broader sustainability and community development goals, even if not explicitly required.
Demonstrate a strong understanding of the specific challenges and opportunities associated with revitalizing historic buildings, including heritage preservation and modern functional adaptation.
Offer a fully integrated design service covering all required disciplines, minimizing the need for the contracting authority to manage multiple sub-consultants.
Key Challenges
Lack of specified evaluation criteria makes it difficult to optimize the bid for scoring.

Focus on comprehensively addressing all mandatory technical requirements with high-quality proposals. Assume that the contracting authority will prioritize technical competence, experience, and a clear understanding of the project's heritage and functional transformation aspects. Present a clear, well-structured bid that demonstrates value and minimizes perceived risk.

The estimated value is relatively low for the scope of work, potentially attracting price-sensitive bidders or leading to scope creep if not managed carefully.

Provide a detailed and realistic cost estimate that reflects the complexity of historic building design and the extensive documentation required. Highlight the value proposition of a thorough and accurate design that minimizes costly changes during construction. Ensure the proposed timeline is achievable within the scope.

Ideal Bidder Profile
An architectural and engineering firm with proven experience in the design and documentation of historic building renovations, particularly those involving adaptive reuse for public or educational functions. The ideal bidder will possess in-house capabilities for all specified design disciplines (architectural, structural, MEP, etc.) and a strong track record of successful project delivery within public funding frameworks.
Key Requirements
Execution of building inventory with a 3D model of the building.
Development of an architectural concept.
Development of an architectural and construction project, including obtaining a building permit.
Development of executive technical designs for all specified sectors (architectural, electrical, water/sewage, gas, telecom, alarm, fire protection, HVAC, operational cost savings, road, land development, small architecture, greenery).
Development of an investor's cost estimate and bill of quantities for all sectors.
Development of Technical Specifications for Construction and Acceptance of Construction Works.
Comprehensive revitalization of a historic residential building (change of building use from residential to service function).
Building revitalization including facade renovation, installation replacement, and interior adaptation for educational purposes.
Key Discriminators
Demonstrated experience in heritage conservation and adaptive reuse of historic buildings.
A robust 3D modeling and BIM (Building Information Modeling) approach for the building inventory and design process.
A proactive approach to identifying and mitigating potential design and construction challenges specific to historic structures.
A clear methodology for achieving operational cost savings (electricity and water consumption) through innovative design solutions for the Ecological Center.
Social Value Opportunities
Commit to incorporating local employment opportunities during the design phase where feasible, and suggest how the final Ecological Center can serve as a community hub for environmental education and engagement.
Bid Focus Areas
Technical Capability Requirements

Address each technical requirement with detailed, evidence-based proposals. For the building inventory, emphasize the use of advanced 3D scanning and modeling techniques. For the design development, showcase a multi-disciplinary team and a phased approach that ensures quality and compliance. Highlight experience in obtaining building permits for complex projects.

Experience in Historic Building Revitalization

Dedicate a significant section to showcasing past projects involving the renovation and adaptive reuse of historic buildings, particularly those with similar functional transformations (e.g., residential to public/educational). Include case studies with before-and-after visuals and testimonials if possible.

Integrated Design Process

Clearly articulate the firm's integrated design process, demonstrating how all disciplines will collaborate from concept to executive design. Emphasize the benefits of this approach, such as improved coordination, reduced errors, and optimized cost savings, especially for operational aspects.

Recommendations7
Thorough 3D Building Inventory and Modeling
CriticalMed effort

Propose a detailed methodology for the building inventory, including the use of advanced laser scanning and photogrammetry to create an accurate 3D model. This model should be the foundation for all subsequent design phases.

Ensures accurate design basis, reduces risk of unforeseen conditions, and demonstrates technical proficiency.
Develop a Strong Narrative on Heritage Preservation and Adaptive Reuse
CriticalHigh effort

Craft a compelling narrative that highlights the firm's understanding of heritage conservation principles and its ability to sensitively transform historic structures into functional, modern spaces like an Ecological Center.

Addresses the core nature of the project and differentiates from general architectural firms.
Showcase Expertise in Operational Cost Savings
HighMed effort

Detail specific design strategies and technologies that will be employed to achieve significant savings in electricity and water consumption, aligning with the 'Ecological Center' theme.

Adds tangible value beyond basic design, aligning with sustainability goals.
Propose a Phased Design Approach
HighMed effort

Outline a clear, phased approach for the design documentation process, from concept to executive designs, including key milestones and deliverables for each phase. This demonstrates project management capability.

Provides clarity and confidence to the contracting authority regarding project execution.
Community Engagement and Educational Legacy
MediumLow effort

Suggest how the design can facilitate community engagement and educational programming within the Ecological Center, and how the project itself can serve as a learning opportunity for local stakeholders.

Adds a layer of social value and aligns with the spirit of urban development programs.
Address Potential Permit Acquisition Challenges
HighMed effort

Acknowledge the potential complexities of obtaining permits for historic building renovations and outline a proactive strategy for engaging with relevant authorities to ensure a smooth process.

Reduces perceived risk for the contracting authority.
Emphasize Integrated BIM Workflow
HighMed effort

Highlight the use of Building Information Modeling (BIM) throughout the design process, from inventory to detailed executive designs, emphasizing its benefits for coordination, clash detection, cost estimation, and lifecycle management.

Demonstrates modern, efficient design practices and adds significant technical credibility.
Competitive Positioning
Position the bid as the most experienced and technically capable partner for revitalizing historic buildings into functional, sustainable public spaces, emphasizing a holistic and integrated design approach that minimizes risk and maximizes long-term value for the Gmina Miejska w Chodzieży and the Polish-Swiss Urban Development Program.

Competitors

Upgrade to see which companies are likely to bid on this tender, based on historical procurement data.

Login

Requirements & Qualifications

12 requirements across 5 categories

Submission (1)
Mandatory (1)
Compliance (1)
Technical (8)
Financial (1)
SUBMISSION REQUIREMENTS1
--No information in the text.
MANDATORY EXCLUSION GROUNDS1
--No information in the text.
ELIGIBILITY REQUIREMENTS1
--No information in the text.
TECHNICAL CAPABILITY REQUIREMENTS8
--Execution of building inventory with a 3D model of the building.
--Development of an architectural concept.
--Development of an architectural and construction project, including obtaining a building permit.
FINANCIAL REQUIREMENTS1
--No information in the text.

Requirements Preview

Sign up to view complete requirements and analysis

Documents

5 documents available with AI summaries

Notice PDFPDF
08de7383-39b3-0183-056e-e50001abcbc8.pdf

This document is a tender notice for the design documentation for the "Heritage in Greenery" project, which involves the modernization and transformation of historic buildings into an Ecological Center within the Polish-Swiss Urban Development Program.

SWZ_CZP_23_02_2026-sig.pdfPDF
SWZ_CZP_23_02_2026-sig.pdf

This document contains the specifications for a public procurement tender for the creation of design documentation for the "Przystań Zdrowia" project, a mental health center funded by the Polish-Swiss Urban Development Programme.

Zalaczniki_do_SWZ_od_1_do_14.zipZIP
Zalaczniki_do_SWZ_od_1_do_14.zip

No summary available for this document.

Zmiana ogłoszenia / Notice ChangePDF
notice_change_08de7399-8aec-702a-056e-e50001a...

No summary available for this document.

Zmiana ogłoszenia / Notice ChangePDF
notice_change_08de745a-7338-315f-056e-e50001a...

No summary available for this document.

Documents Preview

Sign up to view document summaries and analysis

75
Good

Tender Quality Score

This tender for design documentation is generally well-structured, with clear technical requirements and good overall information. However, it lacks explicit evaluation criteria and details on contract duration, impacting its completeness and potentially fairness.

Score Breakdown

Legal Compliance75/100

The tender adheres to general legal requirements by providing a clear CPV code, disclosing the estimated value, and indicating EU funding. The procedure is not specified, which is a minor omission. Deadlines are present, but the submission deadline might be considered short given the scope.

•Submission deadline may be too short
Clarity80/100

The description of the project and the required design documentation is detailed and specific, outlining various technical aspects. The AI-extracted requirements are clearly presented, making it easy for potential bidders to understand the scope of work.

Completeness70/100

Most basic information is present, including title, reference, organization, value, and deadline. However, crucial details such as contract duration and specific evaluation criteria are missing, which affects the overall completeness of the tender documentation.

•Missing evaluation criteria
•Missing contract duration
Fairness85/100

The tender appears fair, with a disclosed value and clear technical requirements that do not seem tailored to specific companies. The use of e-procurement is a positive aspect. The lack of specified evaluation criteria is a concern for transparency.

•Missing evaluation criteria
Practicality65/100

The tender is marked as e-procurement, which is positive. However, there is no explicit mention of e-submission, and the contract start date is not specified. Financing information is implicitly linked to EU funding but not detailed.

•No e-submission mentioned
•Missing contract start date
Data Consistency90/100

Key fields such as title, reference, organization, value, and deadline are populated. There are no indications of suspension or disputes. Dates are logical within the provided information.

Sustainability50/100

The tender mentions 'Greenery' in its title and the creation of an 'Ecological Center,' suggesting a focus on environmental aspects. However, there are no explicit requirements for green procurement, social aspects, or innovation, limiting its sustainability score.

•Not green procurement explicitly
•No social criteria

Strengths

Clear and detailed technical requirements
EU Funded and E-Procurement indicated
Disclosed estimated value and reference number
Active status with available documents

Concerns

Missing evaluation criteria
Missing contract duration and start date
Potentially short submission deadline

Recommendations

1. Specify evaluation criteria to enhance transparency.
2. Provide details on contract duration and start date.
3. Consider extending the submission deadline if feasible given the project scope.

AI Scoring Preview

Sign up to view complete requirements and analysis

Complete quality score analysis
Detailed sub-score breakdown
Strengths & concerns insights
Strategic recommendations

No credit card required • Setup in 2 minutes