Besoin de l'aide d'un expert en appels d'offres ? Découvrez notre service de préparation d'appels d'offres
Retour aux appels d'offres

Services de reporting sur l'état des installations électriques (EICR)

Ouvert
Date limite
1 jours restants
7 octobre 2026
Détails du contrat
Catégorie
Autre
Référence
090383-2026
Valeur
£360,000
Lieu
Essex, Royaume-Uni
Publié
28 septembre 2026
Code CPV
Calendrier du projet

Publication de l'appel d'offres

24 septembre 2026

Date limite pour les questions

30 septembre 2026

Date limite de soumission

7 octobre 2026

Date de début du contrat

30 novembre 2026

Budget
£360,000
Durée
60 mois
Lieu
Essex
Type
Autre

Description originale de l'appel d'offres

Mid and South Essex University Hospitals NHS Foundation Trust (the Trust) is seeking information from suitably qualified and experienced suppliers capable of undertaking Electrical Installation Condition Reports (EICRs) across occupied and operational healthcare facilities using non-disruptive or minimally disruptive testing methodologies. The Trust operates critical healthcare environments that function continuously and therefore requires electrical compliance inspections and testing to be undertaken in a manner that maintains patient safety, supports uninterrupted clinical operations, and minimises disruption to essential services wherever reasonably practicable Scope of Requirement Suppliers are invited to provide information relating to their capability, experience, and methodology for undertaking EICRs within live healthcare environments, including acute hospital sites operating on a 24-hour basis. The Trust seeks a solution that: • Delivers statutory and regulatory compliance. • Minimises the need for planned electrical outages. • Reduces operational disruption to clinical services. • Maintains patient safety and business continuity. • Provides a robust and auditable inspection and testing process. 3. Applicable Standards and Compliance Requirements Suppliers shall demonstrate compliance with all relevant legislation, standards and guidance, including but not limited to: • BS 7671: Requirements for Electrical Installations (current edition). • IET Guidance Note 3: Inspection and Testing. • Electricity at Work Regulations 1989. • HTM 06-01: Electrical Services Supply and Distribution. • HTM 06-02: Electrical Safety Guidance for Low Voltage Systems. • NHS Premises Assurance Model (PAM) requirements where applicable. • NICEIC, ECA, NAPIT or equivalent accredited inspection and testing procedures. Suppliers should demonstrate how their proposed testing methodology satisfies the above requirements whilst supporting the Trust's objective of maintaining service continuity. Testing Without Service Disruption The Trust's preference is for inspection and testing methodologies that minimise or eliminate disruption to clinical and operational services wherever possible. Suppliers shall clearly describe how they will conduct EICRs within operational healthcare facilities whilst avoiding unnecessary interruption to electrical supplies serving critical services. Important clarification The Trust recognizes that certain inspection and testing activities required under BS 7671 may necessitate temporary electrical isolation. The requirement is therefore to avoid unnecessary disruption, apply all reasonably practicable non-disruptive methods first, and tightly control any unavoidable isolation. Where isolation is required, suppliers shall: • Demonstrate that all reasonably practicable non-disruptive testing techniques have been considered. • Clearly identify those tests that require electrical isolation. • Minimise the extent and duration of each isolation. • Provide detailed risk assessments and method statements. • Coordinate all planned outages with the Trust's Estates and Facilities teams. • Maintain continuity of patient care through suitable contingency arrangements. • Provide advance notification of outage requirements. • Clearly define mitigation measures and recovery procedures. • Demonstrate experience in managing electrical testing within live healthcare environments. Suppliers are encouraged to describe any specialist technologies, equipment, software, or recognised industry methodologies that enable condition assessment, fault identification, and compliance verification whilst systems remain energized and operational.

Analyse des risques

L'analyse des risques n'est pas encore disponible pour les appels d'offres de ce pays. Actuellement pris en charge : Estonie, Lettonie, Lituanie, Pologne, France, Royaume-Uni, Danemark, Pays-Bas, Norvège et Finlande.

Stratégie gagnante

Obtenez une stratégie gagnante générée par l'IA et adaptée à cet appel d'offres. Comprend un score de probabilité de succès, les opportunités et défis clés, les axes prioritaires de l'offre, une analyse du positionnement concurrentiel et des recommandations concrètes pour maximiser vos chances.

Se connecter

Concurrents

Passez à un plan supérieur pour voir quelles entreprises sont susceptibles de soumissionner pour cet appel d'offres, basé sur les données historiques.

Se connecter

Exigences et qualifications

L'IA extrait et organise toutes les exigences des documents de l'appel d'offres — qualifications obligatoires, spécifications techniques, conditions financières et règles de soumission — clairement catégorisées pour que vous sachiez exactement ce qui est requis pour soumissionner.

Se connecter

Exigences de base

  • Company registration in EU required
  • Proven track record in similar projects
  • Financial stability documentation

Documents

3 documents disponibles avec des résumés IA

OCDS RecordDOC
090383-2026_ocds_record.json

Aucun résumé n'est disponible pour ce document.

OCDS Release PackageDOC
090383-2026_ocds_release.json

Aucun résumé n'est disponible pour ce document.

Official PDF VersionPDF
090383-2026_official.pdf

Aucun résumé n'est disponible pour ce document.

Aperçu des documents

Inscrivez-vous pour consulter les résumés et l'analyse des documents

Score de qualité

Analyse qualitative complète de cet appel d'offres évaluant la conformité juridique, la clarté, l'exhaustivité, l'équité, la faisabilité, la cohérence des données et la durabilité sur une échelle de 0 à 100 avec une ventilation détaillée et des recommandations.

Se connecter